Call Us Today
+86-13952018524
Home » All Product » LWIR Lens » Manual Focus Lens » FL 50mm F0.8 LWIR Germanium Lens For 1024-768-17um

Other Optical Lens

FL 50mm F0.8 LWIR Germanium Lens For 1024-768-17um

loading

Share to:
pinterest sharing button
twitter sharing button
telegram sharing button
linkedin sharing button
wechat sharing button
whatsapp sharing button
facebook sharing button
sharethis sharing button
Focal Length 50mm F1.0 Long Wave Infrared Germanium Lens For 1024x768-17um Detector.
Availability:
  • RST50F0.8-1024-17

  • Rising

Features of Infrared Lens:

Rising bridges the gap between customers' excellent performance of high precision optical components and limited budget. Remarkably we specialize in the design and manufacture of a wide range of thermal infrared lenses (IR lenses including LWIR, MWIR, and SWIR) for various applications around the globe with superior quality.


Manual Focus Lens Description:

1. Focal Length 50mm F1.0 Long Wave Infrared Germanium Lens For 1024x768-17um Detector.

2. Manual Focus Focal Length, suitable for scenes that are convenient for focusing, such as infrared sights scope, infrared cameras, etc.


Infrared Germanium Lens Application:

1. Airborne

2. Security & Surveillance

3. Maritine & Naval Surveillance

4. Thermography

5. Thermal Imaging Devices(Portable)

6. Defense

7. Enhanced Vision


Infrared Manual Focus Lens Parameters:

Product Name Infrared Germanium Lens
Focal Length 50mm
F# 0.8
Wavelength 8-12um
Image Diagonal 21.76mm
Detector 1024x768-17um
Average Transmission >86%
Circular FOV (H)19.7°x(V)14.8°x(D)24.5°
Back Focus Distance 20mm
Back Working Distance 14mm
Back Focus Length 37.75mm
Dimensions 92mm / 74.61mm
Focus Type Manual Focus
Focus Range 3m to infinity
Mount Type
M55x1-6g
Weight 778g
Operating Temperature -40℃ to +80℃
Storage Temperature -40℃ to +80℃
External Coating AR Coating Available

infrared germanium lens

Infrared Lens Company Profile:

ir lens (5)

Nanjing Rising Photonics Co., Ltd. is recognized as a leader in high-performance infrared optical solutions. The company has professional production equipment and experienced technical team.


The company's main products include infrared lens, germanium lens and other instruments and equipment specially manufactured for the medical, life science, national defense and security, semiconductor and industrial O E M markets.


From optical design to material procurement to mass production, our company is committed to optimizing product performance, cost, quality and delivery time.


In order to ensure product quality, all products of the company will pass strict machine testing and be confirmed with customers before loading and exporting.


We have professional engineer support, efficient sales team and competitive price advantage, attracting customers from all over the world. The products are mainly sold to developed countries and regions such as Southeast Asia, North America, Europe, Russia, Japan, South Korea, etc., and have received wide acclaim and attention, making Rising a reliable supplier for many O E M customers and R&D institutions around the world.


Infrared Lenes Processing Equipment:

ir lens

1. Inner carving test platform;

2. Microscope;

3. Opto Tech aspheric processing;

4. Polishing machine;

5. Thickness Gauge;

6. Ultrasonic Cleaner;

7. Workshop;

8. Interferometer;

9. High and low tempera ture test chamber;

10. High polishing machine;

11. Optical bench;

12. Raul milling;

13. Atomic force microscope;

14. Centralinstrument;

15. Hand Grinding and Polishing Machine;


What Materials Are Suitable For Infrared Lenses?

When designing infrared optical components, various factors related to the optical materials used must be considered. These factors include refractive properties, optical transmission, non-thermal properties, hardness/durability, environmental sensitivity, weight/density, manufacturing technology, and cost. Some of these factors are still interrelated. For example, for some materials, their optical transmittance is high at room temperature, but decreases at higher temperatures. Considering all these factors, when designing infrared optical components, careful consideration of material selection is required. Available materials are: germanium (Ge), silicon (Si), gallium arsenide (GaAs) and cadmium telluride (CdTe); zinc compounds, such as zinc sulfide (ZnS) and zinc selenide (ZnSe); water-soluble crystals, such as Potassium bromide (KBr), sodium chloride (NaCl) and potassium chloride (KCl); fluorides such as magnesium fluoride (MgF2), calcium fluoride (CaF2) and barium fluoride (BaF2); and other materials, Such as fused silica and sapphire; chalcogenide glass, etc.

Previous: 
Next: 

If you have any questions, please contact us via email or telephone and we will get back to you as soon as possible.

Quick Links

Product Category

Contact Us

Copyrights ©2022 Nanjing Rising Opto-Electronic (S) Co., Ltd. All Rights Reserved. Sitemap Support By Leadong